CHOOSING THE RIGHT AQUA SANATURA® UNIT
|
|
AQE-H038 ( G 3/8” ) Is suitable for local
installations immediately before the water tap.
|
|
Example of instalation
|
|
|
AQE-H050 (G 1/2” ) Is suitable for a
standard-sized flat connected to the public water supply.
|
|
Example of instalation
|
|
|
AQE-H075 ( G 3/4” ) Is suitable
for a family house connected to the public water supply or a family house with
its own water well, where a pressure water tank is not used.
|
|
Example of instalation
|
|
|
AQE-H100 ( G 1” ) Is suitable
for a family house with its own water supply, using a water pump and pressure
tank (usually more than 10 litres).
|
|
Example of instalation
|
|
|

|
AQUA SANATURA®
appliances can be installed into a flat or house as an inseparable part of the
water system. When choosing the right position for a new appliance follow the
instruction. Before an installation take off the protective foil. Use a teflon
tape to seal joints.
|
|
The product
needs to be installed vertically with regard to longitudinal axis, so the
intake and outlet of water is in the upper part of the device (picture 1) In this
position the intake (E) is on its side and the outlet (F) is at the top.
|
|
This method
of installation ensures optimal function of the device. Also the item should be
installed before disinfectant feeder and after any filters, UV-lamp (minimal
distance 0.5m).Examples are shown in the pictures 1-4.
|
|
If you have
a private well (picture 3), we recommend that the unit be installed after the
water pump and before water tank (the minimal distance from water pump is 1m).
The device should be installed at least 0.5m from any other
electromagnetic device.
|
|
OBR. 1. INSTALATION IN A FAMILY HOUSE
|
K
|
OBR. 2. INSTALATION IN A FLAT
|
|

|
|

|
•
|
OBR. 3. INSTALATION IN A FAMILY HOUSE WITH ITS OWN WELL
|
|

|
•
|
OBR. 4. LOCA INSTALLATION BEFORE THE TAP
|
K
|
KEY
|
|

|
|
(A) Public
water supply (B) Water
meter (C)
Microfilter (D) Filter
with activated carbon (E) Intake
of the unit (F) Outlet
into the house (G) Outlet
into the flat (H) Well (I) UV lamp (J) Outlet into
the pressure tank (K)
Disinfectant feeder (L) Pressure
tank (M) Outlet
into the taps
|
|
|
TECHNICAL PARAMETERS OF AQUA SANATURA® UNITS
|
|
|
AQE-H 038
|
AQE-H 050
|
AQE-H 075
|
AQE-H 100
|
|
Max. operating pressure [Mpa]
|
0,7
|
0,7
|
0,7
|
0,7
|
|
Operating temperature [+°C]
|
1 - 90
|
1 - 90
|
1 - 90
|
1 - 90
|
|
Intake
|
G 3/8”
|
G 1/2”
|
G 3/4”
|
G 1”
|
|
Outlet
|
G 1/2”
|
G 1/2”
|
G 3/4”
|
G 1”
|
|
Height/Diameter [cm]
|
16/5
|
20/7
|
24/9
|
28/10,4
|
|
Weight [kg]
|
0,8
|
1,6
|
3,2
|
4
|
|
Maximal loss of pressure at
the pressure of 4bar (0,4MPa) is 0,2bar (0,02Mpa).
|
|
AQUA SANATURA®
|
|
Home
Technology and Revitalization What are the Benefits?
Products Customer's Experiences
Medical Point of View
Laboratory Tests
Instalation Instructions
Customer Information
Downloads
Our Company
Contacts
Order our products
Order Our Pricelist
|
RECOMMENDATION
|
|
We
recommend that the Aqua Sanatura device should be installed by a professional
plumber.

|
|
IMPORTANT
|
|
When the device is not used for more than 24 hours, let the water run for a
while before using it, to allow the device to reach its optimum performance.
The device
must not be installed in an area where temperatures fall bellow freezing point
or exceed 90oC !
|
|